Windows Installation Prerequisites for Agentless Data Collector
...
- Machine with Cloudamize Agentless Data Collector installed
- TCP port 445 open inbound
- TCP ports 443 and a proxy server port if a proxy is being used (e.g.,8080, 80) open outbound to our servers at at:
- For assessments on app.cloudamize.com or dashboard.cloudamize.com: 104.197.11.97 (for US infrastructure) and 35.198.133.35 (for EU infrastructure)
- For assessments on console.cloudamize.com or dashboard-partners.cloudamize.com: am.cloudamize.com (for US infrastructure) and am-de.cloudamize.com (for EU infrastructure)
- Each Windows endpoint
- TCP ports 135 and the range 1025-65535 open dynamic RPC port ranges open inbound, appropriate for your OS versions:
- Windows Server 2008 and later: TCP ports 49152 to 65535 open inbound
- Windows Server 2003 and earlier: TCP ports 1025 to 5000 open inbound
- TCP port 445 open outbound to the machine with the Agentless Data Collector installed
- TCP ports 135 and the range 1025-65535 open dynamic RPC port ranges open inbound, appropriate for your OS versions:
- Each Linux endpoint
...
TCP port 22 open inbound
Protocol | Port | Usage |
TCP | 22 | SSH to access Linux servers |
TCP | 135 | Windows RPC |
TCP | 445 | Microsoft-DS Active Directory and SMB, Windows shares |
TCP | 1025-5000 | RPC dynamic port range for Windows Server 2003 and earlier |
TCP | 49152-65535 | RPC dynamic port range for Windows Server 2008 and later |
TCP | 443 | SSL to communicate with the Cloudamize servers |
Fig. 2 Ports relevant to the Cloudamize Agentless Data Collector
Authentication requirements to machines from an Agentless Data Collector
...