Windows Installation Prerequisites for Agentless Data Collector

...

  • Machine with Cloudamize Agentless Data Collector installed

    • TCP port 445 open inbound

    • TCP ports 443 and a proxy server port if a proxy is being used (e.g.,808080) open outbound to our servers at am.cloudamize.com (for US infrastructure), am-de.cloudamize.com (for EU infrastructure), or am-ae.cloudamize.com (for UAE infrastructure). 

      • If your system locally caches DNS resolution, you may need to resolve am.cloudamize.com to 35.171.170.26 or am-de.cloudamize.com to 18.194.12.63 to allow egress traffic. This feature is not currently available for our UAE region.

  • Each Windows endpoint

    • TCP ports 135 and the dynamic RPC port ranges open inbound, appropriate for your OS versions:

      • Windows Server 2008 and later: TCP ports 49152 to 65535 open inbound

      • Windows Server 2003 and earlier: TCP ports 1025 to 5000 open inbound

    • TCP port 445 open outbound to the machine with the Agentless Data Collector installed

  • Each Linux endpoint

    • TCP port 22 open inbound 

...

  • Windows machines require an account in the Administrators group (Domain Admin Account)

  • Linux machines require Root or Wheel access

  • Linux machines cannot have requiretty = true in sudo

  • All other Windows and Linux system requirements apply

...